solarforecastarbiter.validation.validator.check_ac_power_limits¶
-
solarforecastarbiter.validation.validator.
check_ac_power_limits
(power, day_night, capacity, capacity_limit_low=-0.05, capacity_limit_high_day=1.05, capacity_limit_high_night=0.05)[source]¶ Check for extreme AC power.
Parameters: - power (Series) – DC or AC power.
- day_night (Series) – True for day time points, False for night time points.
- capacity (float) – AC capacity.
- capacity_limit_low (float) – Lower bound in fraction of capacity.
- capacity_limit_high_day (float) – Upper bound in fraction of capacity for day time.
- capacity_limit_high_night (float) – Upper bound in fraction of capacity for night time.
Returns: flags (Series) –
- True for values that are within the limits:
- power > capacity * capacity_limit_low, AND * power < capacity * capacity_limit_high_day AND day_night, OR * power < capacity * capacity_limit_high_night AND NOT day_night